Component Testing Tools
MS5308 – Digital LCR Meter with USB interface
It is a professional instrument for measuring inductance, capacitance, and resistance. It has many features, such as automatic identification, automatic measurement range, high measurement accuracy and speed, wide measuring range and so on.An ordinary multimeter only provides DC mode for resistance measurement, while this meter provides both AC and DC measurement modes. A variety of test frequencies up 100kHz can be provided for inductance, capacitance, and resistance in AC mode to meet the actual needs better.
SKU: n/a -
Electrical Power Tools
UNI-T Ut251C High Sensitivity Leakage Current Clamp Meter
UT251C series high-accuracy sensitivity leakage current clamp meters are designed for testing AC leakage current. These high-resolution meters are great for applications such as checking leakage current for motors, home appliances, and other electrical equipment up to 600A.
SKU: n/a
MS5308 – Digital LCR Meter with USB interface
It is a professional instrument for measuring inductance, capacitance, and resistance. It has many features, such as automatic identification, automatic measurement range, high measurement accuracy and speed, wide measuring range and so on.An ordinary multimeter only provides DC mode for resistance measurement, while this meter provides both AC and DC measurement modes. A variety of test frequencies up 100kHz can be provided for inductance, capacitance, and resistance in AC mode to meet the actual needs better.
Compare
Description
Basic Features
● Elevation < 2000m
● Relative Humidity < 80%RH
● Operating TEMP 0℃~40℃
● Dua Display 20000(Main) and 2000(Secondary) counts
● Auto & Manual Ranging
● Auto Power off
● LCR smart check and measurment
● DCR mode
● Series / Parallel measurement mode
● Display Backlight
● Low Battery Display
● Data hold
● RS232 interface
General Accessories
● Power Supply : 8×1.5 AA Batteries
● Product Size : 224mm×172mm×58mm/8.8″×6.8″×2.3″
● Product Weight : 841g/1.85lb
● Certificate : CE / ETL / RoHs
Features
●Resistance Measurement●Capacitance Measurment●Inductance Measurment100Hz/120Hz20.000nF1pF1.0%+5d
Resistance Measurement |
|||
Frequency | Range | Resolution | Accuracy |
100Hz/120Hz | 200.00Ω | 0.01Ω | 1.0%+5d |
100Hz/120Hz | 2.0000kΩ | 0.1Ω | 0.3%+5d |
100Hz/120Hz | 20.000kΩ | 1Ω | 0.3%+5d |
100Hz/120Hz | 200.00kΩ | 0.01kΩ | 0.5%+5d |
100Hz/120Hz | 2.0000MΩ | 0.1kΩ | 1.0%+5d |
100Hz/120Hz | 20.000MΩ | 1kΩ | 1.0%+5d |
100Hz/120Hz | 200.00MΩ | 0.1MΩ | 2.0%+5d |
1kHz | 20.000Ω | 0.001Ω | 1.0%+5d |
1kHz | 200.00Ω | 0.01Ω | 0.3%+5d |
1kHz | 2.0000kΩ | 0.1Ω | 0.3%+5d |
1kHz | 20.000kΩ | 1Ω | 0.3%+5d |
1kHz | 200.00kΩ | 0.01kΩ | 0.5%+5d |
1kHz | 2.0000MΩ | 0.1kΩ | 1.0%+5d |
1kHz | 20.000MΩ | 1kΩ | 2.0%+5d |
1kHz | 200.0MΩ | 0.1MΩ | 5.0%+5d |
10kHz | 20.000Ω | 0.001Ω | 1.0%+5d |
10kHz | 200.00Ω | 0.01Ω | 0.5%+5d |
10kHz | 2.0000kΩ | 0.1Ω | 0.3%+5d |
10kHz | 20.000kΩ | 1Ω | 0.5%+5d |
10kHz | 200.00kΩ | 0.01kΩ | 1.0%+5d |
100kHz | 20.000Ω | 0.001Ω | 1.0%+5d |
100kHz | 200.00Ω | 0.01Ω | 1.0%+5d |
100kHz | 2.0000kΩ | 0.1Ω | 1.0%+5d |
100kHz | 20.000kΩ | 1Ω | 2.0%+5d |
Capacitance Measurment |
|||
Frequency | Range | Resolution | Accuracy |
100Hz/120Hz | 200.00nF | 0.01nF | 0.5%+5d |
100Hz/120Hz | 2000.0nF | 0.1nF | 0.5%+5d |
100Hz/120Hz | 20.000μF | 1nF | 0.5%+5d |
100Hz/120Hz | 200.00μF | 0.01μF | 1.0%+5d |
100Hz/120Hz | 2000.0μF | 0.1μF | 2.0%+5d |
100Hz/120Hz | 20.00mF | 0.1mF | 2.0%+5d |
1kHz | 2000.0pF | 0.1pF | 1.0%+5d |
1kHz | 20.000nF | 1pF | 1.0%+5d |
1kHz | 200.00nF | 0.01nF | 0.5%+5d |
1kHz | 2000.0nF | 0.1nF | 0.5%+5d |
1kHz | 20.000μF | 1nF | 0.5%+5d |
1kHz | 200.00μF | 0.01μF | 1.0%+5d |
1kHz | 2000.0μF | 0.1μF | 1.0%+5d |
10kHz | 200.00pF | 0.01pF | 1.0%+5d |
10kHz | 2000.0pF | 0.1pF | 1.0%+5d |
10kHz | 20.000nF | 1pF | 1.0%+5d |
10kHz | 200.00nF | 0.01nF | 1.5%+5d |
10kHz | 2000.0nF | 0.1nF | 2.0%+5d |
100kHz | 200.00pF | 0.01pF | 2.0%+5d |
100kHz | 2000.0pF | 0.1pF | 1.0%+5d |
100kHz | 20.000nF | 1pF | 2.0%+5d |
100kHz | 200.00nF | 0.01nF | 5.0%+5d |
Inductance Measurment |
|||
Frequency | Range | Resolution | Accuracy |
100Hz/120Hz | 20.000mH | 1μH | 1.0%+5d |
100Hz/120Hz | 200.00mH | 0.01mH | 0.5%+5d |
100Hz/120Hz | 2000.0mH | 0.1mH | 0.5%+5d |
100Hz/120Hz | 20.000H | 1mH | 0.5%+5d |
100Hz/120Hz | 200.00H | 0.01H | 1.0%+5d |
100Hz/120Hz | 2000.0H | 0.1H | 1.0%+5d |
100Hz/120Hz | 20.000KH | 1H | 2.0%+5d |
1kHz | 2000.0μH | 0.1μH | 1.0%+5d |
1kHz | 20.000mH | 1μH | 0.5%+5d |
1kHz | 200.00mH | 0.01mH | 0.5%+5d |
1kHz | 2000.0mH | 0.1mH | 1.0%+5d |
1kHz | 20.000H | 1mH | 1.0%+5d |
1kHz | 200.00H | 0.01H | 2.0%+5d |
1kHz | 2000.0H | 0.1H | 5.0%+5d |
10kHz | 200.00μH | 0.01μH | 1.0%+5d |
10kHz | 2000.0μH | 0.1μH | 0.5%+5d |
10kHz | 20.000mH | 1μH | 0.5%+5d |
10kHz | 200.00mH | 0.01mH | 1.5%+5d |
10kHz | 2000.0mH | 0.1mH | 2.0%+5d |
10kHz | 20.000H | 0.001H | 5.0%+5d |
100kHz | 20.000μH | 0.001μH | 1.0%+5d |
100kHz | 200.00μH | 0.01μH | 2.0%+5d |
100kHz | 2000.0μH | 0.1μH | 2.0%+5d |
100kHz | 20.000mH | 1μH | 2.0%+5d |
100kHz | 200.00mH | 0.01mH | 5.0%+5d |
Trial Update
NET Framework 3.5 included with Windows10 must be turned on before you
install PC Link7 on Windows10
To turn .NET Framework 3.5 on : Click Control Panel, click Programs,
click Turn Windows features on or off, and then select its check box.
There are no reviews yet.